Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

SYNERGYTRANSFORMERSPVTLTD 5a1bd69fb957010b48cf28e5 Products https://www.synergytransformers.in
Power transformers are designed to be used for step-up and step down application in the transmission network of higher voltages like 400 kV, 200 kV, 110 kV, 66 kV, 33kV, etc. The transformers are generally rated 200MVA and above. The designing make the transformers 100% efficient in transmitting heavy load and high voltage i.e., higher than 33 KV. If compared to the size of the distribution transformers, these transformers are bigger and are used in transmission substation, generating station and application areas requiring high insulation level.As these transformers are designed for applications in Transmission Network, thus there is no direct connection with the consumers. Therefore, fluctuations in load are fewer. The transformer is fully loaded 24 hr’s a day, and therefore, throughout the day, Fe losses and Cu losses takes place. The specific Cu weight and Fe weight is very less. These transformers are designed to perform with full efficiency and the average load recorded is near to full load. As these are not dependant on time, so power is considered for the calculation of the efficiency.These transformers seek its application in the Distribution Network and thus, are directly connected to the consumer, resulting in high load fluctuations. Being fully loaded entire day, simultaneously iron losses takes place. But the Cu loss is only at the load cycle. The Fe weight and Cu weight is high, the average load in only 75% of full load. The designing of the transformer supports to ascertain maximum efficiency at 75% of full load. These are dependent on time for entire day and hence, the efficiency is calculated accordingly.
POWER TRANSFORMER
VIEW DETAILS
This BIS Approved Distribution Transformer is designed to provide final voltage transformation to the electric power distribution system. Additionally, the designing and working also makes the transformer ideal to be used for stepping down the voltage that is required in the distribution lines to the degree needed by the customer. The placing of the transformer also plays the role in distributing its name. If it is mounted on a utility pole, the same transformer is termed as pole-mount transformers. On the other hand, if distribution at ground level or underground is required, the transformer is placed on the concrete pads and locked steel cases. These are termed as pad-mount transformers. Therefore, the weight restrictions for the Pole-Mounting Transformer, the transformers are built for primary voltages, i.e., less than 33 kV.
BIS APPROVED DISTRIBUTION TRANSFORMER
VIEW DETAILS
Furnace transformer is designed to meet the requirement of power supply to electric furnace as this lowers the high voltage supply to the furnace. In the mining & metal industry, these transformers seek huge appreciation. The types, voltage and cooling modes vary in order to perfectly cater the needs of the application areas. The excellent cooling modes like forced water cooling mode, self-cooling mode, etc., also make these transformers highly efficient in working.
6 Pulse Furnance Transformers
VIEW DETAILS

Filter using tags

Have any question or need any business consultation?

Have any question or need any business consultation?

Contact Us